Article 12416

Title of the article

IMAGE PREPARATION OF BONE REGENERATE FORMATION PROCESS DURING ADJUSTMENT OF SCANNING ELECTRONIC MICROSCOPES 

Authors

Gerashchenko Sergey Ivanovich, doctor of technical sciences, professor, head of sub-department of medical cybernetics and informatics, Penza State University (440026, 40 Krasnaya street, Penza, Russia), mpo@list.ru
Gerashchenko Sergey Mihailovich, doctor of technical sciences, professor, sub-department of medical cybernetics and informatics, Penza State University (440026, 40 Krasnaya street, Penza, Russia), gsm@pnzgu.ru
Kostenkov Sergey Yur'evich, postgraduate student, Penza State University (440026, 40 Krasnaya street, Penza, Russia), panthfinder@mail.ru 
Yankina Natal'ya Nikolaevna, candidate of technical sciences, associate professor, sub-department of medical cybernetics and informatics, Penza State University (440026, 40 Krasnaya street, Penza, Russia), prisend@yandex.ru 
Karnaukhov Viktor Vyacheslavovich, student, Penza State University (440026, 40 Krasnaya street, Penza, Russia), mpo@list.ru

Index UDK

53.086

DOI

10.21685/2307-4205-2016-4-12

Abstract

Background. Presentation of the process osteointegration using scanning electron microscopy, is largely dependent on the settings of the resolution of the microscope. For the qualitative assessment of the formation of bone regeneration is necessary to ensure the objectivity of the measurement procedures used information technology. Using computer technology, providing the initial information processing requires guaranteed accuracy and metrological reliability of data. In this context, the task of providing the same type of settings for different conditions obtaining exposure, it becomes an integral part of the measurement procedure and is up to date.
Materials and methods. To tune in to the same type modes are encouraged to use electronic tests. They allow you to change the brightness and contrast on the principle of maximum information content of the image. Also available during adjustment of scanning electron microscopes use a preparation of the images and the selection of the objects. This allows you to install the same type of configuration scanning microscope at different levels of resolution and eliminate their impact on the quality of reporting under the control of the formation of bone regeneration.
Results. The proposed method of preparation of the formation of the image of the bone regenerate when configuring scanning electron microscopes can significantly improve the precision of the qualitative characteristics of osseointegration. Adequacy and reliability of the proposed measurement model is confirmed by experimental data.
Conclusions. For the qualitative assessment of the formation of bone regenerate need to further use of electronic tests, to make the adjustment of scanning electron microscope images obtained from dissection and isolation of the objects.

Key words

ostiointegratsiya, the scanning microscopy, test objects, tuning microscope, the preparation of the images

Download PDF

 

Дата создания: 26.05.2017 11:55
Дата обновления: 31.05.2017 15:20